Call (281) 642-9916

Lab Testing for Sand, Fill and Pit Material

Independent labs have tested material from our Plantersville pit. Reports are available on request.

Test reports are available on request

The reports on this page show plasticity index (PI), liquid limit, and the percent of material that passes the #200 sieve. If you would like a copy, call (281) 642-9916 and we can send you one.

If you are building a house pad or ordering select fill, check the specification your builder or engineer gave you. We do not claim that a material meets a project spec unless a report shows that it does. See also residential house pad sites.

What these tests mean

Plasticity index (PI) and liquid limit (LL)
These are Atterberg limits, a standard way to describe how a fine-grained soil behaves as it gets wetter. The liquid limit is the moisture content where the soil starts to flow like a liquid. The plasticity index is the range of moisture where the soil is plastic — stiff enough to mold, but not yet flowing. In plain terms, PI is a measure of how clay-like the soil is. A higher PI usually means more clay, and more shrink and swell as the soil wets and dries. Builders and engineers often specify a PI range for house pad fill and select fill. The right range depends on your project, so check your spec.
Percent passing the #200 sieve
A #200 sieve is a very fine mesh (0.075 millimeters). The percentage that washes through is the fines content — silt- and clay-sized particles. This number matters for compaction, drainage, and whether a material fits a written spec, for example a select-fill or clay-liner specification. A higher percent passing #200 means more fines.
Why this matters for house pads and select fill
A house pad needs fill that can be compacted and that will stay stable under the slab. Many plans call out a PI range, and sometimes a fines content, for the fill that goes in the pad. If you have a spec, call us at (281) 642-9916 and we can talk through the reports we have.

MTEC report, March 8, 2024

On March 8, 2024, MTEC picked up samples at our pit at 11384 Oakwood Drive, Plantersville, TX 77363. The client on the report is Ricky Rickett Sand And Gravel. The samples were tested for Atterberg limits (plasticity index and liquid limit) and percent passing the #200 sieve. Results from the report:

Sample Soil description Plasticity index (PI) Liquid limit (LL) Percent passing #200 sieve
#1Red w/Tan Lean Clay284664
#2Tan w/Red Clayey Sand122932
#3Red Sandey Clay183538

Figures transcribed from the MTEC report dated 03/08/2024. Sample #3 is written as “Sandey Clay” on the report.

MTEC laboratory report dated March 8, 2024, for Ricky Rickett Sand And Gravel, showing plasticity index, liquid limit, and percent passing the #200 sieve for three pit samples.

Click or tap the report to view it larger.

These results describe the three samples that were tested on that date. They are not a guarantee that every load will match these numbers, and they do not by themselves mean the material meets a particular project's specification. Call (281) 642-9916 if you would like a copy of the report.

Kleinfelder report, March 20, 2026

This report covers material from our Plantersville pit that was tested by Kleinfelder for a substation project. The Kleinfelder laboratory test report issued March 20, 2026 (report no. 26-DFW-04122) lists Red & Gray Clayey Sand from Plantersville Mine, tested for the Brazos Elec Plantersville Substation project. The client listed on the report is Hillsboro Materials, LLC dba Hillsboro Sand & Gravel, not Ricky Rickett Sand & Gravel.

The report classifies the material as SC (clayey sand) and lists:

  • Liquid limit (LL): 26
  • Plastic limit (PL): 14
  • Plasticity index (PI): 12
  • Percent passing the #200 sieve: 32
  • Proctor (ASTM D698 A): maximum dry density 122.7 pcf at 10.7% optimum moisture

The report is stamped APPROVED (dated 03/26/2026 on the stamp).

Kleinfelder laboratory test report 26-DFW-04122, issued March 20, 2026, for Red and Gray Clayey Sand from Plantersville Mine, with a Proctor moisture-density curve and an APPROVED stamp.

Click or tap the report to view it larger.

These results describe that sample of material from our Plantersville pit. They do not by themselves mean the material meets any other project's specification.

Aviles Engineering report, January 29, 2020

An Aviles Engineering Corporation report dated January 29, 2020, covers a sample of Reddish Brown Clayey Sand (SC) tested for SpawGlass Civil on the 249 Tollway Mainlanes Construction project. The sample location on the report is listed as “Rickettts.” The proposed use was clay liner material for a detention pond.

Results on the report:

  • Liquid limit (LL): 44
  • Plastic limit (PL): 15
  • Plasticity index (PI): 29
  • Percent passing the #200 sieve: 46.2

The report states that the sample would not meet that project's clay liner specification, which required 65% or more passing the #200 sieve. We show this report as a record that material from the pit was tested. It is not evidence that the material met that liner spec — the report says it did not.

Aviles Engineering report dated January 29, 2020, of classification testing on reddish brown clayey sand for the 249 Tollway project, noting the sample did not meet that project's clay liner specification.

Click or tap the report to view it larger.

Want a copy of a report?

Call (281) 642-9916 for delivery, or come by the pit at 11384 Oakwood Drive, Plantersville, TX 77363. Pit hours: Monday to Friday, 7:00 AM to 5:00 PM.

Call (281) 642-9916

Call (281) 642-9916